F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Administration Errors Result in Exceeding 5% Medication Error Rate

Bath Creek EstatesCuyahoga Falls, Ohio Survey Completed on 03-26-2026

Summary

The facility failed to maintain a medication error rate below 5%, with surveyors identifying 2 errors in 28 medication administration opportunities, resulting in a 7.14% error rate. For one resident with diabetes mellitus who was cognitively intact and received insulin injections daily, the physician’s order directed administration of insulin aspart 23 units SQ with meals. During observation of a medication pass, an LPN removed the insulin aspart pen from the cart, dialed the pen directly to 23 units, attached the needle, and administered the dose without priming the pen. The LPN confirmed she did not prime the pen and acknowledged that her usual practice would be to prime the pen, then dial the required dose, then place the needle on the pen. Manufacturer instructions for the KwikPen specified that the pen must be primed before each injection by selecting 2 units, holding the pen needle-up, tapping to move air bubbles, and pushing the dose knob until insulin is seen at the needle tip before dialing the prescribed dose. In a separate incident, another resident with Crohn’s disease, diverticulosis, constipation, severe cognitive impairment, and frequent bowel incontinence had a physician’s order for MiraLAX powder 17 g PO once daily. During an observed medication administration, an LPN measured the MiraLAX powder by filling the product cap only to just under the very bottom line inside the lid, then poured this amount into water for administration. When asked to read the product instructions, the LPN reviewed the MiraLAX container, which stated that the bottle cap is a measuring cup designed to contain 17 g when filled to the top rim. The LPN confirmed that the MiraLAX had not been measured according to the manufacturer’s instructions. These two observed medication administration errors formed the basis of the cited deficiency under the referenced complaint investigation.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations in Ohio
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Prime Insulin Pens Resulting in Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed an LPN administering insulin to a resident with type 2 DM and daily insulin orders without priming either the lispro or Lantus insulin pens before dialing and giving the doses, contrary to manufacturer instructions requiring priming before each injection. The resident’s blood sugar was elevated, and the LPN confirmed the pens were not primed. This contributed to 2 errors in 25 opportunities, resulting in a medication error rate above the 5% threshold.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Omission Errors Resulting in Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility exceeded the acceptable medication error rate when, during a morning med pass, an RN was unable to administer an ordered dose of Synthroid to a resident with diabetes, hypothyroidism, and hypertension because it was not available in the med cart or emergency box, and also failed to remove a scheduled dose of glipizide from the medication card until prompted by the surveyor. These two omission errors, identified during observation and confirmed in staff interviews and record review, resulted in a 7% medication error rate for 28 observed medication opportunities.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Improper Ophthalmic Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found the facility exceeded the acceptable medication error rate when an LPN administered multiple ophthalmic medications to a resident with complex medical conditions and moderate cognitive impairment. The LPN instilled Atropine and Prednisolone, which were ordered for only one eye, into both eyes, and also gave Brimonidine and Brinzolamide in both eyes without clarifying an incomplete order for Brinzolamide. The LPN did not observe the required time intervals between different eye drops as specified by manufacturer instructions and facility policy, contributing to four medication errors during a single medication pass.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded 5% During Insulin Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility’s medication error rate exceeded 5% when two residents with type 2 DM did not receive insulin as ordered. For one resident, an LPN administered eye drops and oral medications but held the ordered morning Lantus dose without resident refusal, provider notification, or any order parameters to hold the insulin, despite facility policy requiring prescriber contact if a dose is believed inappropriate. For another resident, an RN administered Lantus using a pen device without performing the required priming/safety test steps outlined in the manufacturer’s instructions, instead only checking for air bubbles before injection. These two insulin-related errors, out of 34 observed opportunities, resulted in a 5.8% medication error rate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Omission Leads to Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

A resident with severe cognitive impairment and multiple chronic conditions, including Alzheimer’s disease, diabetes with polyneuropathy, psychotic disorder, hypertension, and severe protein-calorie malnutrition, had physician orders for Preservision AREDS, Protonix, and Refresh Tears. During a medication pass, an LPN did not administer these medications because they were unavailable, which was confirmed by MAR review showing they were not given as ordered. With 28 opportunities for medication administration and three omissions, the facility’s medication error rate was 10.7%, exceeding the 5% threshold, contrary to the facility’s medication administration policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

99.5% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 56 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙