K0918 K918: Have generator or other power source capable of supplying service within 10 seconds.
E

Improper Use of Power Strips in Office Area

Villa At Beecher PlaceFlint, Michigan Survey Completed on 05-21-2025

Summary

Surveyors observed that the facility failed to comply with requirements for electrical systems, specifically regarding the use of power strips. During an inspection, it was found that two power strips were connected together in the social work office. This practice is not in accordance with NFPA 110, NFPA 99, NFPA 111, and NFPA 70 standards, which govern the maintenance and testing of essential electrical systems and are designed to prevent electrical hazards. The observation was made on May 21, 2025, at approximately 10:50 AM, and the findings were confirmed through an interview with the maintenance director at the time of observation. The report notes that this deficient practice could affect 15 occupants in the event of an electrical-related fire. No additional details about specific residents or their medical conditions were provided in the report.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
See other K0918 citations in Ohio
Failure to Maintain and Document Required Generator Testing and Safety Features
F
K0918 K918: Have generator or other power source capable of supplying service within 10 seconds.
Short Summary

Surveyors found that the facility failed to maintain required documentation showing that its three generators were tested monthly and inspected and tested annually in accordance with NFPA 99 and NFPA 110. Despite multiple requests, no records of these tests or inspections were provided. During the facility tour, surveyors also observed that none of the three generators were equipped with remote manual stop buttons, and this was confirmed by the Maintenance Director. This deficient practice had the potential to affect all residents in the facility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Required Generator Load Bank Testing and Documentation
F
K0918 K918: Have generator or other power source capable of supplying service within 10 seconds.
Short Summary

The facility did not complete the required four-hour load bank test of its diesel generator within the mandated 36-month period and failed to properly document engine hours during monthly tests, as confirmed by the Maintenance Director. This lapse affected the reliability of the essential electrical system for all residents.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

99.5% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 64 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙