F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Error Rate Exceeds Regulatory Threshold Due to Multiple Administration Errors

Good Shepherd VillageSpringfield, Ohio Survey Completed on 05-01-2025

Summary

The facility failed to maintain a medication error rate below five percent, as evidenced by three medication errors observed out of 25 opportunities, resulting in a 12 percent error rate. In one instance, a resident with severe cognitive impairment and multiple diagnoses, including major depressive disorder and dementia, was administered 10 mg of Namenda instead of the physician-ordered 5 mg. The LPN responsible confirmed the error during an interview. In another case, a resident with similar cognitive and psychiatric conditions was given crushed Plavix and Wellbutrin Extended Release, as well as the contents of an Auvelity capsule, mixed into pudding. The LPN acknowledged crushing the medications, despite manufacturer instructions stating that Wellbutrin Extended Release tablets should be swallowed whole to prevent rapid drug release and increased side effects. A third medication error involved a resident with a recent femur fracture, MRSA, and diabetes, who required insulin administration for a high blood glucose reading. The RN administering Lispro insulin failed to prime the insulin pen before injection, as required by manufacturer guidelines, which could result in an incorrect dose being delivered. The RN confirmed the omission during a post-administration interview. These observed errors contributed to the facility's medication error rate exceeding the regulatory threshold.

Penalty

20 days payment denial
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations in Ohio
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors and Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified an 11.1% medication error rate when an LPN did not administer a resident’s ordered nifedipine ER dose because it was not available in the cart or pyxis, and proceeded with the rest of the medications. In a separate instance, an RN administered furosemide despite the order having been discontinued and gave magnesium oxide instead of the ordered SlowMag, explaining that he relied on scanning multi-drug packets rather than individually verifying each medication against the MAR, and knowingly substituted magnesium oxide when SlowMag was unavailable.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to keep its medication error rate below 5% when a resident with dementia, COPD, diabetes, and depression did not receive ordered doses of Singulair and calcium/vitamin D3 because the medications were not available at the time of administration. An RN attempted to pass the morning medications but was unable to administer these two ordered drugs, and later confirmed their unavailability, resulting in two errors out of 33 medication opportunities and an overall error rate of 6.06%.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Crushing of Do-Not-Crush Medications Leads to Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility’s medication error rate exceeded 5% after observing an LPN crush and administer four medications that were listed on the facility’s do-not-crush list. A resident with atrial fibrillation, polyosteoarthritis, and GERD was ordered Metoprolol Succinate ER (two strengths totaling 75 mg daily), Pantoprazole Sodium delayed release, and Tylenol eight hour arthritis pain ER. Despite a standing order that explicitly excluded delayed release/ER and do-not-crush medications from being crushed, the LPN crushed all four of these medications and gave them mixed in pudding, resulting in four medication errors out of 34 opportunities and an 11.76% error rate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Result in Exceeding 5% Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed two medication administration errors that caused the facility’s medication error rate to exceed 5%. In one case, an LPN administered insulin using a pen device to a resident with diabetes without priming the pen as required by the manufacturer’s instructions. In another case, an LPN measured a resident’s ordered 17 g dose of MiraLAX by filling the product cap only partway instead of to the top rim as specified on the container, then administered the inaccurately measured dose. These actions resulted in a calculated medication error rate of 7.14% during the survey.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Prime Insulin Pens Resulting in Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed an LPN administering insulin to a resident with type 2 DM and daily insulin orders without priming either the lispro or Lantus insulin pens before dialing and giving the doses, contrary to manufacturer instructions requiring priming before each injection. The resident’s blood sugar was elevated, and the LPN confirmed the pens were not primed. This contributed to 2 errors in 25 opportunities, resulting in a medication error rate above the 5% threshold.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

99.5% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 64 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙